Clinical Alert Fatigue: Why a Good Sepsis Model Still Buries Nurses in Alarms

On a simulated 30-bed unit, a sepsis model with an AUC of 0.92 at onset still sent 25.7 false alerts for every real one when it scored hourly. A 24-hour lockout cut alerts by 47% for 2.6 points of sensitivity; raising the threshold to make the same cut cost 15.7.

Clinical alert fatigue chart: on a simulated 30-bed unit, alerting on every threshold crossing at 95% per-score specificity gives 11.1 sepsis alerts a day and catches 71.0% of cases; a 24-hour lockout gives 5.8 alerts a day and catches 68.4%; raising the threshold to 98% gives 5.4 alerts a day and catches 55.3%

Clinical alert fatigue starts with the scoring clock

Clinical alert fatigue gets blamed on bad models, and some of it is. But a sepsis model can separate septic from non-septic patients well at the moment that matters and still send nurses 25 false alerts for every real one. The reason sits in a setting most validation reports leave out: how often the model scores each patient, and what the alerting rule does with all those scores.

A model that scores a patient every hour gets about 96 looks at a four-day stay. Each look is a fresh chance for a stable patient's score to drift over the line. The per-score specificity on a vendor slide, 95% or 99%, describes one look. The nurse experiences the stay.

This piece runs that problem on one simulated medical-surgical unit over ten years. The model is good: at the hour of sepsis onset its scores separate septic from non-septic patients with an AUC of 0.92. Three alerting policies and three thresholds produce very different days for the nurses, and one policy change halves the alert count for almost nothing. The code is below, it runs in under five seconds, and the Clinical Alert Math demo runs the companion calculation in your browser.

One unit, ten simulated years

The unit has 30 beds, always full. Stays last a median of about four days (a mean of 4.4). Sepsis develops in 6% of stays, close to the 6.6% of hospitalizations that met the sepsis definition in the Michigan Medicine validation of the Epic Sepsis Model. Staffing is one nurse to five patients, the ratio California's Title 22 sets for medical-surgical units, so six nurses cover the unit on each 12-hour shift.

Every hour, each patient gets a risk score. Part of it is a persistent baseline, since some patients look sicker than others for their whole stay. Part is hour-to-hour noise with an autocorrelation of 0.9, since vital signs and labs drift rather than jump. Patients who become septic also carry a signal that ramps from zero to 2 standard deviations over the 12 hours before onset.

For a non-septic patient the score at any hour is standard normal, so a threshold of 1.645 gives 95% per-score specificity, 2.054 gives 98%, and 2.326 gives 99%. At onset, a septic patient's score is shifted up by 2 standard deviations, and the AUC between the two is Φ(2/√2) = 0.921. By the usual yardstick this is a good model, far above the 0.63 that Wong and colleagues measured for the Epic Sepsis Model at Michigan in 2021.

An alert counts as true if sepsis onset follows within 24 hours. Septic patients leave the unit six hours after onset. Everything else is a false alert.

The three policies:

  1. Every crossing: fire each time the score rises from below the threshold to above it.
  2. 24-hour lockout: fire on a crossing, then stay silent for that patient for 24 hours.
  3. Once per stay: fire on the first crossing and never again.

The simulation code

"""Clinical alert fatigue: what hourly scoring does to a 30-bed unit."""
import numpy as np
from statistics import NormalDist

RNG = np.random.default_rng(17)
BEDS, YEARS = 30, 10
HOURS = 24 * 365 * YEARS
P_SEPSIS = 0.06            # share of stays that develop sepsis
SD_BASE, RHO = 0.6, 0.9    # persistent patient effect; hourly autocorrelation
SD_NOISE = np.sqrt(1 - SD_BASE**2)   # non-septic scores are N(0, 1) per hour
SIGNAL, RAMP = 2.0, 12     # signal at onset (in SDs), hours of ramp before onset
LOOKBACK = 24              # an alert counts as true if onset follows within 24h
PER_NURSE = 5              # California's med-surg ratio, 1 nurse to 5 patients


def simulate_stays():
    """Yield (bed, start hour, hourly scores, onset hour or None) per stay."""
    for bed in range(BEDS):
        t = 0
        while t < HOURS:
            los = int(max(24, RNG.lognormal(np.log(96), 0.5)))   # median 4 days
            onset = None
            if RNG.random() < P_SEPSIS and los > 18:
                onset = int(RNG.integers(12, los))
                los = min(los, onset + 6)        # transferred out after onset
            e = np.empty(los)
            e[0] = RNG.normal()
            shocks = RNG.normal(size=los) * np.sqrt(1 - RHO**2)
            for h in range(1, los):
                e[h] = RHO * e[h - 1] + shocks[h]
            s = RNG.normal(0, SD_BASE) + SD_NOISE * e
            if onset is not None:
                h = np.arange(los)
                s += SIGNAL * np.clip((h - (onset - RAMP)) / RAMP, 0, 1)
            yield bed, t, s, onset
            t += los


def alerts(scores, thr, policy):
    """Hours at which an alert fires under each policy."""
    above = scores >= thr
    cross = np.flatnonzero(above & ~np.r_[False, above[:-1]])
    if policy == "every crossing":
        return cross
    if policy == "24h lockout":
        out, last = [], -10**9
        for h in cross:
            if h - last >= 24:
                out.append(h)
                last = h
        return np.array(out, dtype=int)
    return cross[:1]                                       # once per stay


STAYS = list(simulate_stays())


def run(thr, policy):
    fired = np.zeros((BEDS, HOURS))
    tp = fp = caught = septic = clean = clean_flagged = 0
    for bed, start, s, onset in STAYS:
        a = alerts(s, thr, policy)
        if onset is None:
            clean += 1
            clean_flagged += len(a) > 0
            fp += len(a)
        else:
            septic += 1
            true = (a >= onset - LOOKBACK) & (a <= onset)
            tp += true.sum()
            fp += (~true).sum()
            caught += true.any()
        for h in a:
            if start + h < HOURS:
                fired[bed, start + h] += 1
    shifts = fired.reshape(BEDS // PER_NURSE, PER_NURSE, -1, 12).sum(axis=(1, 3))
    return dict(
        per_score_spec=NormalDist().cdf(thr),
        clean_flagged=clean_flagged / clean,
        sensitivity=caught / septic,
        alerts_per_day=(tp + fp) / (365 * YEARS),
        false_per_true=fp / max(tp, 1),
        per_nurse_shift=shifts.mean(),
        heavy_shifts=(shifts >= 3).mean(),
    )


if __name__ == "__main__":
    print(f"stays: {len(STAYS):,}  septic: {sum(o is not None for *_, o in STAYS)}")
    for thr in (1.645, 2.054, 2.326):
        for policy in ("every crossing", "24h lockout", "once per stay"):
            r = run(thr, policy)
            print(f"spec/score {r['per_score_spec']:.3f}  {policy:<15}"
                  f"  clean stays flagged {r['clean_flagged']:6.1%}"
                  f"  sens {r['sensitivity']:6.1%}"
                  f"  alerts/day {r['alerts_per_day']:5.1f}"
                  f"  false per true {r['false_per_true']:5.1f}"
                  f"  per nurse-shift {r['per_nurse_shift']:4.2f}"
                  f"  shifts 3+ {r['heavy_shifts']:6.1%}")

The output, with the columns trimmed into a table:

stays: 24,761  septic: 1474
Per-score specificityPolicyClean stays flaggedSepsis caughtAlerts per dayFalse per trueAlerts per nurse-shift
95%Every crossing46.6%71.0%11.125.70.92
95%24h lockout46.6%68.4%5.820.10.48
95%Once per stay46.6%53.1%3.314.50.28
98%Every crossing27.6%55.3%5.416.70.45
98%24h lockout27.6%53.9%3.113.10.26
98%Once per stay27.6%47.2%2.09.70.17
99%Every crossing17.7%44.0%3.012.10.25
99%24h lockout17.7%43.5%1.99.60.15
99%Once per stay17.7%39.3%1.47.60.11

Per score, per stay, per shift

Start with the 99% row. One score in a hundred from a non-septic patient crosses the line, which sounds quiet. Over a stay, 17.7% of non-septic patients set off at least one alert. At 95% per score, nearly half of them do (46.6%). The reason is arithmetic, not model quality: only 1.3% of the 2.63 million scored hours in the simulation fall in the 24 hours before a sepsis onset. Almost every look the model takes is a look at a patient who will not become septic, and a few of those looks will cross any threshold you choose.

At 95% per-score specificity with an alert on every crossing, the unit gets 11.1 sepsis alerts a day and 25.7 false alerts for every true one. Per nurse, that averages 0.92 alerts per 12-hour shift, and 9.7% of nurse-shifts carry three or more. That load sounds bearable until you remember that the sepsis model is one alarm source among many. The Joint Commission's 2013 Sentinel Event Alert on alarm safety estimated that 85% to 99% of alarm signals do not require clinical intervention. A sepsis alert that is wrong 25 times for each time it is right teaches the same lesson as the monitor that beeps when an electrode dries out.

Halving the alerts: a lockout or a higher threshold

Say the nurse managers ask for half as many alerts. There are two ways to get there from the 95% every-crossing row.

Raise the threshold to 98%. Alerts fall from 11.1 a day to 5.4, a cut of 51.5%. Sensitivity falls from 71.0% to 55.3%: 15.7 percentage points of the unit's septic patients no longer get an alert in the 24 hours before onset.

Keep the threshold and add a 24-hour lockout. Alerts fall to 5.8 a day, a cut of 47.5%. Sensitivity falls to 68.4%, a loss of 2.6 points.

The lockout works because most of the extra alerts under every-crossing are repeats: the same patient's score bouncing around the line, firing, dipping and firing again. Those repeats rarely add a catch the first alert didn't already make. Raising the threshold removes alerts from every patient at once, including the septic patients whose scores were rising toward it.

The lockout does leave more false alerts per true one (20.1 against 16.7), because it keeps a first alert on every patient whose score crosses the lower line. If the goal is fewer interruptions while keeping the catches, the lockout wins. If the goal is a better ratio at any cost in missed cases, the threshold does. The chart at the top of this piece draws both curves across thresholds from 90% to 99.5%. Wherever the two curves cover the same alert volume, the lockout catches more sepsis.

Once per stay is the extreme version and it overshoots. Its single alert often fires on noise days before onset, and then the patient has no alert left. Sensitivity drops to 53.1% at the 95% threshold.

The AUC a sepsis alert needs

The simulation shows what scoring frequency does to a good model. The other half of clinical alert fatigue is how good the model has to be in the first place. The Clinical Alert Math demo uses an equal-variance binormal model: non-case scores follow N(0, 1), case scores follow N(d, 1), and AUC = Φ(d/√2). Turn the question around and ask what AUC an alert needs to hold false alerts to k for each true one, at sensitivity Se and prevalence p:

FPR = (Se · p · k) / (1 − p), d = Phi^− 1(Se) + Phi^− 1(1 − FPR), AUC = Phi(d / √2)

The first expression is Bayes' rule solved for the false positive rate that gives a positive predictive value of 1/(1 + k). The second is the separation between the two score distributions when the threshold catches Se of the cases and lets through that false positive rate, and the third turns the separation into an AUC. In code:

from statistics import NormalDist

N = NormalDist()


def required_auc(prevalence, sensitivity, false_per_true):
    fpr = sensitivity * prevalence * false_per_true / (1 - prevalence)
    if fpr >= 1:
        return None
    d = N.inv_cdf(sensitivity) + N.inv_cdf(1 - fpr)
    return N.cdf(d / 2 ** 0.5)


def day(screened, prevalence, auc, sensitivity):
    d = 2 ** 0.5 * N.inv_cdf(auc)
    spec = N.cdf(d - N.inv_cdf(sensitivity))
    cases = screened * prevalence
    tp, fp = cases * sensitivity, (screened - cases) * (1 - spec)
    return spec, tp + fp, fp / tp


spec, alerts, fpt = day(500, 0.02, 0.80, 0.80)
print(f"demo preset: spec {spec:.3f}, {alerts:.1f} alerts/day, {fpt:.1f} false per true")
for prev in (0.02, 0.06):
    row = [required_auc(prev, 0.80, k) for k in (2, 5, 10)]
    print(f"prevalence {prev:.0%}: " + " / ".join(f"{a:.3f}" for a in row))
print(f"AUC 0.921 scored once, 6%, 71% sensitivity: {day(1000, 0.06, 0.921, 0.71)[2]:.1f} false per true")
demo preset: spec 0.636, 186.2 alerts/day, 22.3 false per true
prevalence 2%: 0.971 / 0.943 / 0.901
prevalence 6%: 0.932 / 0.855 / 0.718
AUC 0.921 scored once, 6%, 71% sensitivity: 1.6 false per true
Prevalence per screenAUC for 2 false per trueAUC for 5AUC for 10
2%0.9710.9430.901
6%0.9320.8550.718

At 80% sensitivity and 6% prevalence, holding nurses to two false alerts per real case takes an AUC of 0.932. At 2% prevalence it takes 0.971. The demo's sepsis preset (500 patients screened a day, 2% prevalence, an AUC of 0.80, 80% sensitivity) lands at 186.2 alerts a day and 22.3 false per true, because hitting 80% sensitivity at that AUC drags specificity down to 63.6%. Michigan's validation of the Epic Sepsis Model, at an AUC of 0.63 and the threshold of 6, found a positive predictive value of 12% and missed 67% of patients with sepsis.

The last line of that output ties the two halves together. Screened once per stay, at a moment when septic patients carry their full signal, a model with the simulation's AUC of 0.92, at 6% prevalence and the 71.0% sensitivity of the 95% every-crossing rule, would send 1.6 false alerts per true one. Scored hourly on the simulated unit, it sent 25.7. The model did not change between those two numbers; the scoring clock and the alert rule did, which is why they belong in any validation report next to the AUC.

Where it breaks

The score model is mine and it is simple. Real risk scores are not standard normal, their noise is not a clean AR(1) process, and the signal before onset does not ramp in a straight line. Change the autocorrelation or the spread of patient baselines and the size of the lockout's advantage changes with them. So I reran the comparison across nine combinations, each time raising the every-crossing threshold until its alert volume matched the lockout's:

import numpy as np
from statistics import NormalDist
import alert_sim as A   # the simulation above, saved as alert_sim.py

z = NormalDist().inv_cdf
for rho in (0.8, 0.9, 0.95):
    for sd_base in (0.4, 0.6, 0.8):
        A.RHO, A.SD_BASE = rho, sd_base
        A.SD_NOISE = np.sqrt(1 - sd_base**2)
        A.RNG = np.random.default_rng(17)
        A.STAYS = list(A.simulate_stays())
        base = A.run(z(0.95), "every crossing")
        lock = A.run(z(0.95), "24h lockout")
        for spec in np.arange(0.95, 0.999, 0.001):    # same volume by threshold
            thr = A.run(z(spec), "every crossing")
            if thr["alerts_per_day"] <= lock["alerts_per_day"]:
                break
        print(f"rho {rho:<4} baseline sd {sd_base}:  lockout costs "
              f"{100 * (base['sensitivity'] - lock['sensitivity']):4.1f} points, "
              f"threshold {spec:.3f} costs "
              f"{100 * (base['sensitivity'] - thr['sensitivity']):4.1f}")
rho 0.8  baseline sd 0.4:  lockout costs  2.8 points, threshold 0.977 costs 13.0
rho 0.8  baseline sd 0.6:  lockout costs  3.2 points, threshold 0.979 costs 15.5
rho 0.8  baseline sd 0.8:  lockout costs  3.5 points, threshold 0.981 costs 17.4
rho 0.9  baseline sd 0.4:  lockout costs  3.2 points, threshold 0.977 costs 14.3
rho 0.9  baseline sd 0.6:  lockout costs  2.6 points, threshold 0.978 costs 14.0
rho 0.9  baseline sd 0.8:  lockout costs  3.2 points, threshold 0.979 costs 14.2
rho 0.95 baseline sd 0.4:  lockout costs  2.6 points, threshold 0.978 costs 14.6
rho 0.95 baseline sd 0.6:  lockout costs  2.5 points, threshold 0.978 costs 14.5
rho 0.95 baseline sd 0.8:  lockout costs  2.0 points, threshold 0.978 costs 12.9

In every combination the lockout cost 2.0 to 3.5 points of sensitivity, and a threshold raised to the same alert volume cost 12.9 to 17.4. The gap is stable across these settings. The exact figures still belong to a synthetic score, not to any product.

The 24-hour window that counts an alert as true is a choice. A shorter window marks more alerts false and makes early warnings look worse. Michigan scored the Epic model every 15 minutes, four times as often as this simulation, so a 15-minute model has even more chances to cross.

A lockout also has a clinical cost the simulation does not model: a patient who deteriorates fast in the 24 hours after a false alert gets no second warning. One answer is a hard ceiling, a score so high it fires regardless of the lockout. Test any such rule on your own retrospective data before using it.

And none of this is clinical advice. These are synthetic patients on a made-up unit, built to show how scoring frequency, thresholds and alert rules interact.

Running the numbers for your own unit

Ask your vendor or your data team for three things the AUC leaves out: how often the model scores each patient, what share of non-septic stays get at least one alert, and how many alerts each patient receives on average. If the third number is well above one, a lockout is worth testing before anyone moves the threshold. Then report sensitivity, alerts per nurse per shift and false alerts per true one at each candidate rule, side by side, on last year's encounters.

The Clinical Alert Math demo sets a unit's screened patients, prevalence, AUC, target sensitivity and nurse minutes per alert, and shows alerts per day, false alarms per real case, missed cases and nurse time. The earlier piece on the shared math of clinical alerts works the same Bayes arithmetic across sepsis, deterioration, stroke and capacity. More of this work is in the healthcare analytics research hub and the machine learning and analytics hub, both run from Vector 1 in Kansas City.